Most of the boiler calls we get in Hale are not really about the boiler. They are about the fact that somebody fitted a combi to a house that was never going to be happy with one.
The arithmetic is simple and it is unforgiving. A combi makes hot water on demand through a single heat exchanger. Ask it for one shower and it is excellent. Ask it for two showers, a bath and the kitchen tap on a February morning and it physically cannot — not because it is a bad boiler, but because no combi can. Houses in Hale routinely have four or five hot outlets that get used at the same time, and that is a system boiler and a properly sized unvented cylinder, every time.
Sizing the cylinder is where the thought goes. The question is not how many bathrooms you have, it is how many run at once and for how long. For most large Hale houses that lands between 250 and 300 litres. Undersize it and you have swapped one disappointment for another.
Before any of that we measure the incoming main. An unvented cylinder needs a decent flow rate to be worth having, and some of the older properties round here still have a supply pipe that will not deliver it — sometimes because it is old and narrow, occasionally because it is lead. That test takes two minutes at the stopcock and it changes the whole design, so it happens at the survey rather than on the day.
One thing worth thinking about if you are replacing a boiler here now: if a heat pump is anywhere in your ten year plan, the radiator upsizing and the cylinder are the same work either way. Doing it once with the boiler, rather than twice, is a genuine saving.
The housing stock here, what it means for heating generally, and the other work we do in Hale — all on one page rather than repeated across this one.
Because you have a combi trying to serve more outlets than one heat exchanger can. It is not a fault and a bigger combi will not really fix it. Stored hot water from a cylinder will.
It depends on simultaneous demand rather than bedroom count. For most of the larger houses in Hale it works out at 250 to 300 litres. We size it against how your household actually uses hot water in the morning.
MCS certified. The grant comes off the quote, not out of your pocket.
Wet UFHThe lowest flow temperature in the house. The best thing you can pair with a heat pump.
BathroomsTanked properly, drained properly, and the pressure worked out before we start.
Controls & zoningWeather compensation does more than an app ever will.
AreaThe full picture of what we do here, and what the housing stock means for it.
Hale is a short drive from our yard in Altrincham, and we know this housing stock before we arrive — large period detached, and the simultaneous-demand problem.
Every job here starts the same way: a survey, a heat loss calculation, and a fixed written price with no surprises.
Free survey, no obligation. We are in Hale most weeks — it is a short drive from the yard.